BSL series low frequency Online UPS  3 in 3 out 600KVA
  • BSL series low frequency Online UPS  3 in 3 out 600KVA
0

BSL series low frequency Online UPS 3 in 3 out 600KVA

Capacity (KVA):600KVA Rated capacity:480KW Voltage range:380Vac or 400Vac or 415Vac ±25%Three-phase five-wire input frequency range:40-70Hz output voltage:380Vac or 400Vac or 415Vac ±1%

  • Product detail
  • Model

    BSL33600

    Capacity(KVA)

    600KVA

    Rated capacity

    480KW

    input

    Voltage range

    380Vac or 400Vac or 415Vac ±25%Three-phase five-wire input

    frequency range

    40-70Hz

    power factor

    0.97 (add filter)

    output

    output voltage

    380Vac or 400Vac or 415Vac ±1%

    output frequency

    Automatic tracking of bypass frequency

    Output waveform

    Sinusoidal THDV1%100% linear load

    power factor

    0.8

    Overload capacity

    Load 110%60minLoad 125%10 minLoad150%1min

    Conversion time

    Municipal Electricity-Battery

    0ms

    bypass

    Rated voltage

    380Vac /400Vac/415Vac±25%

    Phase

    Three-phase five-wire input

    frequency range

    50-60 Hz ± 2 (±0.5, ±1, ±2,±3 Adjustable)

    Battery

    Battery Voltage

    480VDC

    communication

    Communication interface

    Dry Contact RS232 Communication Interface

    work environment

    Operating temperature

    0~40

    relative humidity

    0~95%No dew  GB/T 3859.2 Specify derating usage

    Storage temperature

    -20~55

    Working altitude

    < 1500m, count 1500m when it over1500m

    physical characteristics

    Net weight (Kg)

    3700

    Reference dimension WDH

    2800×1040×1900mm


    Model

    BSL33600

    Capacity(KVA)

    600KVA

    Rated capacity

    480KW

    input

    Voltage range

    380Vac or 400Vac or 415Vac ±25%Three-phase five-wire input

    frequency range

    40-70Hz

    power factor

    0.97 (add filter)

    output

    output voltage

    380Vac or 400Vac or 415Vac ±1%

    output frequency

    Automatic tracking of bypass frequency

    Output waveform

    Sinusoidal THDV1%100% linear load

    power factor

    0.8

    Overload capacity

    Load 110%60minLoad 125%10 minLoad150%1min

    Conversion time

    Municipal Electricity-Battery

    0ms

    bypass

    Rated voltage

    380Vac /400Vac/415Vac±25%

    Phase

    Three-phase five-wire input

    frequency range

    50-60 Hz ± 2 (±0.5, ±1, ±2,±3 Adjustable)

    Battery

    Battery Voltage

    480VDC

    communication

    Communication interface

    Dry Contact RS232 Communication Interface

    work environment

    Operating temperature

    0~40

    relative humidity

    0~95%No dew  GB/T 3859.2 Specify derating usage

    Storage temperature

    -20~55

    Working altitude

    < 1500m, count 1500m when it over1500m

    physical characteristics

    Net weight (Kg)

    3700

    Reference dimension WDH

    2800×1040×1900mm


Looking more